The Webhook channel accepts inbound messages at its configured HTTP path. channels.webhook is disabled by default. When enabled, it defaults to 0.0.0.0:8080 and /webhook. This is separate from the Gateway's /api/v1/message endpoint.

Configuration

channels:
  webhook:
    enabled: true
    host: 127.0.0.1
    port: 8080
    path: /webhook
    secret: ""
    max_pending: 1000

An empty secret disables signature checks. Set a nonempty secret and a trusted network entry point before exposing the channel. The general configuration loader does not expand environment placeholders in YAML; override the field through the process environment:

export ECHO_AGENT_CHANNELS__WEBHOOK__SECRET="$WEBHOOK_SECRET"

Request and signature

curl -X POST http://127.0.0.1:8080/webhook \
  -H 'Content-Type: application/json' \
  -d '{"sender_id":"ci-1","chat_id":"builds","text":"analyze the failed build","wait":false}'

text must be nonempty. Missing sender_id and chat_id each default to webhook. content is an alternative to text; metadata is optional. wait defaults to false.

With a nonempty secret, X-Signature must contain the raw hexadecimal HMAC-SHA256 digest of the exact request-body bytes, without a sha256= prefix. For example:

import hashlib
import hmac

signature = hmac.new(secret.encode(), request_body_bytes, hashlib.sha256).hexdigest()
headers = {"X-Signature": signature}

A missing or invalid signature returns HTTP 403. Invalid JSON or fields return 400.

Response

With wait: false, successful queue admission returns HTTP 200 and {"status":"accepted","event_id":"..."}. With wait: true, the connection waits for the final reply; success returns HTTP 200 and {"response":"...","event_id":"..."}. A 120-second wait timeout returns 504. Failed turns include status, error, response, and event_id, with an HTTP status determined by the turn result. This channel does not stream responses or send an asynchronous callback. To inspect an accepted event's turn state, query Gateway GET /api/v1/turns/{event_id} with management authorization.

max_pending limits only requests waiting synchronously for a reply; exceeding it returns 503. Inbound queue rejection also returns 503. Use an Idempotency-Key or X-Idempotency-Key header (or body idempotency_key) for safe retries; reusing a key with different content returns 409. See idempotent retries.